Resolute Synergy and Fusion
Synergy + Fusion
TWO APPS WORKING SEAMLESSLY AS ONE

Connect. Configure. Use.

All in a single day

Our solution consists of two complementary software applications that seamlessly work together to allow you to quickly connect your building, collect and configure data, apply analytic rules to your data, and use the resulting analytic insights to better understand and improve your building’s performance.

synergyLogo_2.png
Immediate Value
Building Configuration

Used to connect buildings to the Resolute Cloud™ and to configure these buildings to capture the correct data in the correct formats to ensure the best analytics results.

fusionLogo_1.png
Ready-to-Use Analytics

Analytics & Reporting

Used after the integration process to access analytical insights, charts, reports, scorecards, and action items related to equipment performance and energy usage.

Redefining how building performance is done 

AHU / RTU

Building Static Pressure

Cooling Command

Damper Position

Discharge Air Fan Command (single or common)

Discharge Air Fan Frequency (single or common)

Discharge Air Fan Speed (single or common)

Discharge Air Fan Status (single or common)

Discharge Air Flow

Discharge Air Humidity

Discharge Air Pressure

Discharge Air Pressure Setpoint

Discharge Air Temp Setpoint

Discharge Air Temperature

Exhaust Air Flow

Heating Command

Mixed Air Temp

Occupied Cooling Setpoint

Occupied Heating Setpoint

Occupied Mode

Outside Air Damper Command (open/closed)

Outside Air Damper Minimum Position Setpoint

Outside Air Flow

Outside Air Flow Minimum Setpoint

Outside Air Humidity

Outside Air Temperature

Return Air Flow

Return Air Humidity

Return Air Pressure

Return Air Temp

Zone Humidity

Zone Pressure

Zone Temperature

BOILER

Boiler Command

Boiler Leaving Setpoint

Boiler Status

Entering Water Temperature

Heating Command

Leaving Water Temperature

CHILLED WATER

Chilled Water Entering Temperature

Chilled Water Leaving Temperature

Chilled Water Setpoint

Chiller Command

Chiller Status

Condenser Water Entering Temperature

Condenser Water Leaving Temperature

Cooling Command

Outside Air Temperature

COOLING TOWER

Condenser Water Circ Pump Status

Condenser Water Entering Temperature

Condenser Water Leaving Temperature

Enable Command

Sump Temperature

FCU

Cooling Command

Heating Command

METERS

Domestic Water Volume Total (accumulated)

Energy Total (accumulated)

Gas Volume Total (accumulated)

VAV

Damper Position

Discharge Air Fan Status (single or common)

Discharge Air Flow

Discharge Air Flow Setpoint

Discharge Air Temperature

Occupied Cooling Setpoint

Occupied Heating Setpoint

Occupied Mode

Reheat Command

Return Air Flow

Zone Humidity

Zone Temperature

Zone Temperature Deviation

We take security as seriously as you do

Resolute is SOC-2 compliant—the gold standard of data security.

SOC-2-Web-logo only.png
  • Access Control

  • Two-factor Authentication

  • Encryption

  • Access Control

  • Encryption

  • Network/Application Firewalls

  • Network/Application Firewalls

  • Two-factor Authentication

  • Intrusion Detection

  • Performance Monitoring

  • Disaster Recovery

  • Security Incident Handling

  • Quality Assurance

  • Processing Monitoring

connect@2x.png

Connect quickly and begin pulling data immediately

configure@2x.png

Integrate in hours instead of weeks or months

Use@2x.png

Access analytical insights and see results by day's end

Direct Cloud-to-Cloud Connection

Automated Configuration

Pre-defined Analytics Rules Library

On-demand Performance Reports

Deep-dive Energy Analytics

Real-time Fault Detection & Alerts

Root-cause Analysis & Solutions

Prioritized Action Items & Tracking

You shouldn't have to write the rules that make the analytics work. That's our job.

Quickly map the following key points into Resolute Synergy™—our patent-pending building configuration tool—and apply our library or hundreds of pre-defined analytics rules (based on ASHRAE 90.1 and ASHRAE High Performance standards) to thousands of pieces of equipment in just a few clicks.

Points-to-Rules Summary
Ponts2rulessummary1.png
Change the variables for any rule to suite your specific requirements
Our rules feed the reports that help you get important things done.
Report Icon
Zone | VAV Report
Report Icon
High Demand Zone Report
Report Icon
OR Compliance Report
Report Icon
OR Performance Report
Report Icon
AHU | RTU Operations Report
Report Icon
VAV Controller Performance Report
Report Icon
VAV Economizer Performance Report
Report Icon
AHU Scheduling Report
Report-6-tilt2.png
Become indispensable
with Resolute®

Deliver levels of customer value you probably never thought possible.

Download our solution overview brochure